236 200 1005 Stainless steel DHW cylinder with integrated 100 L buffer volume, XL 316L heat exchanger and in-line connections.
This combination unit offers more domestic hot water storage than the 200 L version while adding 100 L of buffer volume to the system. It is suited to projects with higher hot water demand and a need for smoother system operation.
The 30 m AISI 316L heat exchanger helps the heat pump transfer energy efficiently to the domestic water. Together with the integrated buffer volume, it supports more stable heat pump operation.
By combining hot water storage and buffer volume in one black stainless steel unit, the installation remains clearer, more compact and professionally finished.
Technical specifications - PDWT 300+100 32mm
| General | |
| Product type | Stainless steel heat pump cylinder with integrated buffer tank |
| Rated volume | 100 L |
| Actual volume | 81 L |
| Application | Heat pump / domestic hot water and buffer storage |
| Installation type | Vertical floor-standing |
| Connection layout | Combined DHW and buffer connections in one vertical line |
| Number of exchangers | 1 |
| Height [mm] | 1907 |
| Tilt dimension [mm] | 2015 |
| Outer diameter [mm] | 650 |
| Inner diameter [mm] | 550 |
| Insulation | CFC-free rigid PU foam |
| Insulation thickness [mm] | 50 |
| Outer casing | Frosted metal, Black |
| Weight [kg] | 80 |
| Warranty | 3 years |
| Tank | |
| Tank material | Stainless steel Duplex 2205 |
| Max. operating / test pressure | 6/10 bar |
| Max. tank temperature [°C] | 95 |
| Heat exchanger | |
| Exchanger type | XL heat pump corrugated coil heat exchanger |
| Exchanger design | Corrugated pipe coil |
| Exchanger diameter [mm] | 32 mm |
| Exchanger material | AISI 316L stainless steel |
| Exchanger length [m] | 30 |
| Exchanger surface area [m²] | 4.5 |
| Exchanger volume [L] | 19 |
| Max. exchanger pressure [bar] | 10 |
| Max. exchanger temperature [°C] | 95 |
| Connections | ||||
| H | DN 14 | G 3/4" | P&T safety valve | 1907 mm |
| B | DN 3 | G 1" | Connection (inlet / outlet) | 1672 mm |
| F | DN 9 | G 1" | Ø32 mm AISI 316L XL heat exchanger 30 m | 1572 mm |
| C | DN 15 | Thermometer | 1395 mm | |
| P | DN 5 | G 3/4" | Sensor pocket 1 (12.7 mm) | 1246 mm |
| D | DN 7 | G 3/4" | Sensor pocket 2 (12.7 mm) | 1010 mm |
| L | DN 8 | G 1" | Ø32 mm AISI 316L XL heat exchanger 30 m | 910 mm |
| L | DN 6 | G 1½" | Electric heating element | 910 mm |
| A | DN 4 | G 1" | Connection (inlet / outlet) | 810 mm |
| G | DN 2 | G 1/2" | Drain port | 597 mm |
| S | DN 34 | G 3/4" | P&T safety valve | 495 mm |
| J | DN 23 | G 1" | Connection (inlet / outlet) | 350 mm |
| N | DN 29 | G 1" | Connection (inlet / outlet) | 350 mm |
| R | DN 25 | G 3/4" | Sensor pocket 4 (12.7 mm) | 290 mm |
| T | DN 26 | G 1½" | Electric heating element | 290 mm |
| I | DN 24 | G 1" | Connection (inlet / outlet) | 230 mm |
| M | DN 28 | G 1" | Connection (inlet / outlet) | 230 mm |
| Q | DN 22 | G 1/2" | Drain port | 33 mm |
| Safety requirements |
| The storage vessel must be protected against overpressure at all times. We recommend installing the following safety accessories: * Safety valve and inlet combination * Nexus sanitary expansion vessel * Nexus expansion vessel for heating systems The required expansion vessel capacity must be calculated according to the total system volume and operating conditions. |