The Nexus PAWT-300H LE2 is a Duplex 2205 stainless steel solar water heater with two exchangers: a large hygienic flow-through DHW exchanger and a separate solar exchanger.
The Nexus PAWT-L LE2 is a stainless steel solar water heater with two integrated heat exchangers for solar thermal systems, heat pump support and professional domestic hot water applications.
The large hygienic AISI 316L corrugated exchanger produces shower water in flow-through operation. The separate smaller solar exchanger is used for the solar thermal circuit, while the heat pump can be connected to the water volume of the inner tank.
This configuration combines solar input, buffer volume and hygienic domestic hot water production in one Duplex 2205 stainless steel vessel. The design is well suited to installers who need a flexible solution for solar thermal and heat pump based systems.
Models up to and including 300 litres are supplied with Energy Efficiency Class A. The PU insulation, sensor pockets, electric backup connection and frosted-metal outer casing support efficient operation and professional installation.
Technical data - PAWT-300H LE2 Solar
| General | |
| Product type | Stainless steel solar water heater with two heat exchangers |
| Rated volume | 300 L |
| Application | Solar thermal / heat pump / domestic hot water |
| Installation type | Horizontal, floor-standing |
| Connection layout | Connections according to technical drawing |
| Number of heat exchangers | 2 |
| Width [mm] | 1560 |
| Tilt height [mm] | 1672 |
| Outer diameter [mm] | 600 |
| Inner diameter [mm] | 500 |
| Insulation | CFC-free rigid PU foam |
| Insulation thickness [mm] | 50 |
| Outer casing | Frosted metal, RAL 7030 |
| Weight [kg] | |
| Warranty | 5 years |
| Tank | |
| Tank material | Stainless steel Duplex 2205 |
| Max. tank pressure [bar] | 10 |
| Max. tank temperature [°C] | 95 |
| Heat Exchanger 1 | |
| Exchanger type | Solar corrugated coil heat exchanger |
| Exchanger design | Ø28 mm corrugated pipe coil |
| Exchanger material | AISI 316L stainless steel |
| Exchanger length [m] | 15 |
| Exchanger surface area [m²] | 2.0 |
| Exchanger volume [L] | 7 |
| Max. exchanger pressure [bar] | 10 |
| Max. exchanger temperature [°C] | 95 |
| Heat Exchanger 2 | |
| Exchanger type | Hygienic flow-through corrugated heat exchanger |
| Exchanger design | Ø28 mm corrugated pipe coil |
| Exchanger material | AISI 316L stainless steel |
| Exchanger length [m] | 20 |
| Exchanger surface area [m²] | 2.5 |
| Exchanger volume [L] | 9 |
| Max. exchanger pressure [bar] | 10 |
| Max. exchanger temperature [°C] | 95 |
| Connections | ||||
| B | Width | 1560 mm | ||
| ØD | Outer diameter | 600 mm | ||
| Ød | Inner diameter | 500 mm | ||
| H | DN 14 | G 3/4"f | P&T safety valve | 500 mm |
| M | DN 14 | G 3/4"f | P&T safety valve | 773 mm |
| K | DN 9 | G 1"f | Hot water outlet | 460 mm |
| F | DN 3 | G 1"f | Ø28 mm solar heat exchanger inlet | 360 mm |
| E | DN 4 | G 1"f | Ø28 mm solar heat exchanger outlet | 240 mm |
| A | DN 1 | G 1"f | Ø28 mm hygienic flow-through heat exchanger inlet | 360 mm |
| D | DN 2 | G 1"f | Ø28 mm hygienic flow-through heat exchanger outlet | 240 mm |
| G | DN 8 | G 1"f | Cold water inlet | 140 mm |
| I | DN 6 | G 1½"f | Electric heating element | 330 mm |
| L | DN 5 | G 1/2"f | Sensor pocket 1 | 1244 mm |
| L | DN 7 | G 1/2"f | Sensor pocket 2 | 1244 mm |
| P | DN 16 | G 1/2"f | Drain tap | 115 mm |
| Safety notice |
| The storage vessel must be protected against overpressure at all times. We recommend installing the following safety accessories: • Safety valve and inlet combination • Nexus sanitary expansion vessel • Nexus expansion vessel for heating systems The required expansion vessel capacity must be calculated according to the total system volume and operating conditions. |