Nexus Next A+ NEXT 200+100 2-in-1 Duplex 2205 stainless steel heat pump boiler with 100L buffer tank, extra-thick PU insulation and Ø32 mm high-flow heat exchanger.
The Nexus Next A+ NEXT 200+100 combines a Duplex 2205 stainless steel domestic hot water boiler with a lower 100 litre buffer tank in one compact unit.
The A+ energy label is supported by extra-thick PU insulation, reducing standby heat loss and keeping stored heat available for longer.
The integrated Ø32 mm AISI 316L corrugated heat exchanger is designed for modern heat pumps with higher flow requirements and efficient heat transfer.
The lower buffer section increases system volume, improves hydraulic stability and helps reduce frequent heat pump cycling.
Technical data - NEXT 200+100
| General | |
| Product type | A+ 2-in-1 stainless steel heat pump boiler with lower buffer tank |
| Rated volume | 200+100 L |
| DHW boiler volume | 200 L |
| Buffer volume | 100 L |
| Application | Domestic hot water and heat pump buffer function |
| Installation type | Vertical floor-standing |
| Connection layout | Upper DHW boiler with lower 100 L buffer tank |
| Number of heat exchangers | 1 |
| Height [mm] | 1962 |
| Tilt height [mm] | 2064 |
| ØD Outer diameter [mm] | 640 |
| Ød Inner diameter [mm] | 500 |
| Insulation | CFC-free rigid PU foam |
| Insulation thickness [mm] | 70 |
| Outer casing | Frosted metal, RAL 7030 |
| Weight [kg] | 78 |
| Warranty | 3 years |
| Tank | |
| Upper DHW tank material | Stainless steel Duplex 2205 |
| Lower buffer tank material | Stainless steel AISI 304 |
| Max. tank pressure [bar] | 6 |
| Max. tank temperature [deg C] | 95 |
| Heat Exchanger | |
| Exchanger type | High-flow corrugated heat pump heat exchanger |
| Exchanger design | Ø32 mm corrugated pipe coil |
| Exchanger material | AISI 316L stainless steel |
| Exchanger length [m] | 25 |
| Max. exchanger pressure [bar] | 10 |
| Max. exchanger temperature [deg C] | 95 |
| Connections | ||||
| H | Height | 1962 mm | ||
| ØD | ØD Outer diameter | 640 mm | ||
| Ød | Ød Inner diameter | 500 mm | ||
| H | DN 14 | G 3/4" | P&T safety valve | 1962 mm |
| B | DN 3 | G 1" | Connection inlet/outlet | 1702 mm |
| F | DN 9 | G 1 1/4" | Ø32 mm AISI 316L stainless steel XL heat exchanger 25 m, inlet/outlet | 1702 mm |
| C | DN 5 | G 1/2" | Sensor pocket (1) (12.7 mm) | 1425 mm |
| P | DN 15 | G 1/2" | Sensor pocket (2) (12.7 mm) | 1226 mm |
| L | DN 6 | G 1 1/2" | Electric heating element | 1020 mm |
| D | DN 7 | G 1/2" | Sensor pocket (3) (12.7 mm) | 940 mm |
| A | DN 4 | G 1" | Connection inlet/outlet | 840 mm |
| E | DN 8 | G 1" | Ø32 mm AISI 316L stainless steel XL heat exchanger 25 m, inlet/outlet | 840 mm |
| G | DN 2 | G 1/2" | Drain tap | 627 mm |
| S | DN 34 | G 3/4" | P&T safety valve | 569 mm |
| J | DN 23 | G 1" | Connection inlet/outlet | 359 mm |
| N | DN 29 | G 1" | Connection inlet/outlet | 359 mm |
| R | DN 25 | G 1/2" | Sensor pocket (4) (12.7 mm) | 309 mm |
| T | DN 26 | G 1 1/2" | Electric heating element | 244 mm |
| I | DN 24 | G 1" | Connection inlet/outlet | 244 mm |
| M | DN 28 | G 1" | Connection inlet/outlet | 244 mm |
| Safety notice |
| The storage vessel must be protected against overpressure at all times. We recommend installing the following safety accessories: - Safety valve and inlet combination - Nexus sanitary expansion vessel - Nexus expansion vessel for heating systems The required expansion vessel capacity must be calculated according to the total system volume and operating conditions. |